Long Life WiFi Repeater with UC Healthy Living Certificate

Basic DataDimension(mm)26.5×23.5×15Weight ( g )≈40gContact Arrangement1A/1BContact MaterialAgSnO2Ambient Temperature-22~+55ºCVibration10~55Hz,1.5mmShock1000m/s²,(100g)Specifications DataNominal Voltage9VPower Consumption<3WOperating Voltage12VMax. Motor Voltage18VMax. Switching Current80ASurge 

Featured Products

Long Endurance WiFi Relay with UC Certificate for Health LifeLong Endurance WiFi Relay with UC Certificate for Health Life

Long Endurance WiFi Relay with UC Certificate for Health Life
Basic DataDimension(mm)26.5×23.5×15
Weight ( g )≈40g
Contact Arrangement1A/1B
Contact MaterialAgSnO2
Ambient Temperature-22~+55ºC
Vibration10~55Hz,1.5mm
Shock1000m/s²,(100g)
Specifications DataNominal Voltage9V
Power Consumption<3W
Operating Voltage12V
Max. Motor Voltage18V
Max. Switching Current80A
Surge Current6000A/10ms
Motor Resistance14±2Ω
Contact Rating(Res)250VAC,80A
Contact Voltage<60mV
Contact Resistance<1.0
Dielectric StrengthMotor to Contact4000VAC,50/60Hz 1min
Across Open Contact2000VAC,50/60Hz 1min
Electrical Life(120 cycles/H)5,000
Mechanical Life(3600 cycles/H)100,000
Pulse TimeAdvise 30ms~40ms
Picking-up Time(@9V)<=25ms
Release Time(@9V)<=25ms
Insulation Resistance>=1000MΩ(500VDC)
Long Endurance WiFi Relay with UC Certificate for Health Life
Long Endurance WiFi Relay with UC Certificate for Health Life
Long Endurance WiFi Relay with UC Certificate for Health Life
Long Endurance WiFi Relay with UC Certificate for Health LifeLong Endurance WiFi Relay with UC Certificate for Health LifeLong Endurance WiFi Relay with UC Certificate for Health LifeLong Endurance WiFi Relay with UC Certificate for Health Life
          Cautions of Latching Relay:

             1.Suggestions of relay's input
            (1)Polarity-Please check the polarity inside of our technical specification, if single coil then"+ -" or "- +"are fine,
            you can change it by one pulse.If double coil then it's necessary to confirm "-+-" or "+-+"before leaving the our factory.
            (2)Driving-Please energize the relay at our recommend pulse width, rated voltage for reliable performance, if 1.5
            times or 2 times of value or lower driving condition plz confirm with our engineer.
            (3)Relays'contact status may be changed during transportation or installation due to impact of external force,
            therefore please reset to the required status.
 
            2.Suggestions of relay's output
            (1)When choosing the relay with hard connection,please avoid the external force on load terminals during or after
            the installation.
            (2)When the relay will be connected with screw or bolts to the relays' terminals, plz make sure your connection is
            fastened and prevent relay from damages or other safety problems due to temp. Rise..
            (3)The sampling signal wires of products are limited, please do not pull or torque during installation.

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours