Contec Cms70A Labtop Oximeter for Hospitals, Home Healthcare, Oxygen Bars, Community Medical Centers

CONTEC CMS70A labtop Oximeter used in Hospital, Home Healthcare, Oxygen Bar, Community Medical Center Product DescriptionModel:CMS70A   Brand:CONTECInstructionsCMS70A Spo2 Monitor can be used in measuring the pulse oxygen saturation and pulse rate through finger.1.SpO2 value display-Pulse rate value-bar graph-PI d

Featured Products

CONTEC CMS70A labtop Oximeter used in Hospital, Home Healthcare, Oxygen Bar, Community Medical Center
 

Product Description


Model:CMS70A   Brand:CONTEC

Instructions


CMS70A Spo2 Monitor can be used in measuring the pulse oxygen saturation and pulse rate through finger.

1.SpO2 value display
-Pulse rate value
-bar graph
-PI display
-Pulse waveform
2.Patient Range:Adult,Pediatric,Neonatal
3.Data storage function, and the storage data can be uploaded to computer

Major Features

1.low power consumption
2.Menu operation
3.Screen brightness can be changed
4.Pulse rate sound indication, it can be turned on or turned off
5.With measured data overruns limits and low-voltage alarm function, the upper/down alarm range can be adjustable
6.Battery capacity indication
7.Low-voltage indication: Low-voltage indicator appears before working abnormally which is due to low-voltage, and with alarm function
8.Connected with an external oximeter probe


Main performance

1.Display Mode: TFT Screen and LED display
2.Screen Resolution: 320*240
3.SpO2 Measuring Range: 0%~100%(the resolution is 1%)
4.Accuracy: 70%~100%: ± 2%, Below 70% unspecified.
5.PR Measuring Range: 30bpm~250bpm(the resolution is 1bpm)
6.Accuracy: ± 2bpm or ± 2% (select larger)
7.Measurement Performance in Weak Filling Condition: SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ± 4%, pulse rate error is ± 2 bpm or ± 2% (select larger).
8.Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ± 1%.
9.Power Consumption: About 350mA
10.Voltage: AC 100~240V, 50/60HZ
11.Power Supply: Built-in recharge Li-Polymer
12.Battery working hour: After the device built-in battry finished the charge, it's continuous working time is not less than 1 hour
13.Safety Type: II device, BF Type

Accessories

Sell in standard
-user manual
-power wire
-data line
-oximeter probe(Adult)
-disk (PC software)

Sell in addition
Other oximeter probe(Pediatric or Neonatal)

Physical Identity

Dimension: 269(L)× 222(W)× 79(H)mm
Weight: About 1Kg

 

Detailed Photos


Contec Cms70A Labtop Oximeter Used in Hospital, Home Healthcare, Oxygen Bar, Community Medical Center

Contec Cms70A Labtop Oximeter Used in Hospital, Home Healthcare, Oxygen Bar, Community Medical Center

Product List


-TELEMEDICINE products

-Pulse oximeter
-Patient Monitoring
-ECG machine(Electrocardiograph)/Holter ECG/Stress test ECG,
-EEG,
-Ultrasound Imaging,Pocket fetal doppler,fetal monitor,
-Blood pressure Monitor(ABPM),
-spirometer
-infusion/syringe Pump
-Digital Stethscope
-In-Vitro Diagnostics
-simulator
-Veterinary products

Company Profile

Contec Cms70A Labtop Oximeter Used in Hospital, Home Healthcare, Oxygen Bar, Community Medical CenterContec Cms70A Labtop Oximeter Used in Hospital, Home Healthcare, Oxygen Bar, Community Medical CenterContec Cms70A Labtop Oximeter Used in Hospital, Home Healthcare, Oxygen Bar, Community Medical CenterContec Cms70A Labtop Oximeter Used in Hospital, Home Healthcare, Oxygen Bar, Community Medical Center


 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours